TY - JOUR
T1 - Two-step accelerating freezing protocol yields a better motility, membranes and DNA integrities of thawed ram sperm than three-steps freezing protocols
AU - Galarza, Diego A.
AU - López-Sebastián, Antonio
AU - Woelders, Henri
AU - Blesbois, Elizabeth
AU - Santiago-Moreno, Julián
N1 - Publisher Copyright:
© 2019 The Authors
PY - 2019/12
Y1 - 2019/12
N2 - The present study compares a protocol that mimics freezing of ram semen in static nitrogen vapor with two protocols with an initial low cooling rate in the first step, followed by higher cooling rates where ice nucleation occurs. Semen ejaculates, obtained from twelve adults rams, were diluted with TEST-based extender and frozen with either Protocol 1 (three-step decelerating cooling): from +5 °C to −35 °C (40 °C/min), from −35 °C to −65 °C (17 °C/min), and then from −65 °C to −85 °C (3 °C/min); or Protocol 2 (three-step accelerating cooling): from +5 °C to −5 °C (4 °C/min), from −5 °C to −110 °C (25 °C/min), and then from −110 °C to −140 °C (35 °C/min); or Protocol 3 (two-step accelerating cooling), from +5 °C to −10 °C (5 °C/min), and then from −10 °C to −130 °C (60 °C/min). Post-thaw sperm quality was reduced for all protocols (p < .05) compared with fresh semen. Post-thaw percentages of sperm motility characteristics and sperm with intact plasma membrane, intact acrosome, and intact mitochondrial membrane were greater using Protocol 3 than Protocol 2 (p < .05) and Protocol 1 (p < .01). In addition, the post-thaw percentage of sperm with fragmented DNA was lower (p < .05) using Protocol 3 compared with Protocol 1. The present results indicate that a cooling rate of 60 °C/min around and after the time point of ice nucleation provided better post thaw survival and function of ram sperm than lower (and/or decelerating) cooling rates.
AB - The present study compares a protocol that mimics freezing of ram semen in static nitrogen vapor with two protocols with an initial low cooling rate in the first step, followed by higher cooling rates where ice nucleation occurs. Semen ejaculates, obtained from twelve adults rams, were diluted with TEST-based extender and frozen with either Protocol 1 (three-step decelerating cooling): from +5 °C to −35 °C (40 °C/min), from −35 °C to −65 °C (17 °C/min), and then from −65 °C to −85 °C (3 °C/min); or Protocol 2 (three-step accelerating cooling): from +5 °C to −5 °C (4 °C/min), from −5 °C to −110 °C (25 °C/min), and then from −110 °C to −140 °C (35 °C/min); or Protocol 3 (two-step accelerating cooling), from +5 °C to −10 °C (5 °C/min), and then from −10 °C to −130 °C (60 °C/min). Post-thaw sperm quality was reduced for all protocols (p < .05) compared with fresh semen. Post-thaw percentages of sperm motility characteristics and sperm with intact plasma membrane, intact acrosome, and intact mitochondrial membrane were greater using Protocol 3 than Protocol 2 (p < .05) and Protocol 1 (p < .01). In addition, the post-thaw percentage of sperm with fragmented DNA was lower (p < .05) using Protocol 3 compared with Protocol 1. The present results indicate that a cooling rate of 60 °C/min around and after the time point of ice nucleation provided better post thaw survival and function of ram sperm than lower (and/or decelerating) cooling rates.
KW - Cooling
KW - DNA integrity
KW - Ram
KW - Semen cryopreservation
KW - Semen quality
UR - https://www.scopus.com/pages/publications/85074036491
U2 - 10.1016/j.cryobiol.2019.10.007
DO - 10.1016/j.cryobiol.2019.10.007
M3 - Artículo
C2 - 31628908
AN - SCOPUS:85074036491
SN - 0011-2240
VL - 91
SP - 84
EP - 89
JO - Cryobiology
JF - Cryobiology
ER -