TY - GEN
T1 - Accuracy of connected confidence left ventricle segmentation in 3-D multi-slice computerized tomography images
AU - Medina, Ruben
AU - Bautista, Sebastian
AU - Morocho, Villie
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2018/1/4
Y1 - 2018/1/4
N2 - Cardiovascular diseases are the main cause of death in the World. This fact has motivated different actions for prevention, diagnosis and monitoring of cardiovascular diseases. In this work, the accuracy of a connected confidence left ventricle segmentation method is performed. This task is accomplished using a software platform for left ventricle segmentation of 3-D cardiac Multi-Slice Computerized Tomography (MSCT) images that is also described. The software platform has as a goal performing research about efficient methods for cardiac image segmentation and quantification. The accuracy assessment of the segmentation method is performed by comparing the estimated segmentation with respect to segmentations manually traced by cardiologists. Results show that the segmentation method provides Dice Similarity coefficients higher than 0.90 with low computational cost. The obtained segmentation is able to include within the left ventricular lumen the papillary trabeculae muscles, enabling further accurate estimation of the left ventricular mass.
AB - Cardiovascular diseases are the main cause of death in the World. This fact has motivated different actions for prevention, diagnosis and monitoring of cardiovascular diseases. In this work, the accuracy of a connected confidence left ventricle segmentation method is performed. This task is accomplished using a software platform for left ventricle segmentation of 3-D cardiac Multi-Slice Computerized Tomography (MSCT) images that is also described. The software platform has as a goal performing research about efficient methods for cardiac image segmentation and quantification. The accuracy assessment of the segmentation method is performed by comparing the estimated segmentation with respect to segmentations manually traced by cardiologists. Results show that the segmentation method provides Dice Similarity coefficients higher than 0.90 with low computational cost. The obtained segmentation is able to include within the left ventricular lumen the papillary trabeculae muscles, enabling further accurate estimation of the left ventricular mass.
KW - Connected confidence
KW - Left ventricle segmentation
KW - Multi-slice computerized tomography
KW - Software platform
UR - https://www.scopus.com/pages/publications/85045738426
U2 - 10.1109/ETCM.2017.8247499
DO - 10.1109/ETCM.2017.8247499
M3 - Contribución a la conferencia
AN - SCOPUS:85045738426
T3 - 2017 IEEE 2nd Ecuador Technical Chapters Meeting, ETCM 2017
SP - 1
EP - 6
BT - 2017 IEEE 2nd Ecuador Technical Chapters Meeting, ETCM 2017
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2nd IEEE Ecuador Technical Chapters Meeting, ETCM 2017
Y2 - 16 October 2017 through 20 October 2017
ER -